DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1606SYSAM (Circuit Pack)

9
no Aux Data. This error entry indicates that the SYSAM DPR Test failed and that the SYSAM circuit pack should be replaced.If the test i s be ing r un fro m som ewher e othe r tha n the PPN G3-MT o r SYSAM Remote Access connection (for example, EPN G3-MT), the test results will be displayed on the screen.
Table 9-606. Test #910 SYSAM Dual Port RAM Test
Error
Code Test
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
1318
1335
2029
2033
2500
ABORT Internal system error
1. Retry the command.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
This may be caused by a planned interchange initiated automatically during 24
hour scheduled testing.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby SYSAM circuit pack in the standby SPE
carrier because the standby SPE is unavailable.
1. Ref er to t he STBY-SPE ma inten ance doc umenta tion f or inf ormat ion on why
a standby SPE may be unavailable and what repair actions should be
taken. The screen for the status spe command should indicate that
handshake is down. This may be caused by a variety of reasons such as
the SPE-SELECT switches on the DUPINT circuit packs being set to the
position of the active SPE, a failure of the DUPINT circuit pack, or loss of
power on the standby SPE. The SPE selected field on the status spe
screen displays spe a or spe b if b oth SPE-SELECT switches are in the a
or b positions, resp ectively.
2000 ABORT Response to the test request was not received within the allowable time period.
If the s ystem is a Hi gh or C ritic al Reli abil ity c onfig urati on and if th e SYSAM
circ uit p ack i s on the stand by SPE, this ab ort c ode m ay ind ica te tha t the
stand by SPE is not res pond ing to the h ands hake m essag e. If t his is t he ca se,
the standby SPE maintenance software may take up to two minutes to indicate
that handshake communication with the standby SPE is down. The ABORT
code then c hang es to 1 339 (s tand by SPE una vaila ble).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
Continued on next page