DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1603SYSAM (Circuit Pack)
9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below when
inspecting errors in the sys tem. By clearing error cod es associated with the

SYSAM Reset Test

, for example, you may also clear errors g enerated from other
tests in the testing sequenc e.
Notes:
a. If you are invoking the long test seq uence from the PPN G3-MT, the
SYSAM Reset Test and SYSAM DPR Test will cause the PPN G3-MT to
logo ff and tear d own a ny SYSAM Re mote A cce ss co nnec tion. After the
test s eque nce r uns, t he Error Log s hould be e xamin ed fo r SYSAM err ors
of typ e 1 an d 204 9 to d eterm ine if eithe r SYSAM Res et Test or SYSA M
DPR Test have failed. If you are invoking the long demand test sequenc e
from an EPN G3-MT, all tests listed above will run and the results will
display on the EPN G3-MT. The PPN G3-MT will still be logged off and any
SYSAM Remote Access connection will be torn d own.
b. These tests can be run only on the ac tive SYSAM circuit pack. If you are
invoking the long test sequenc e on the standby SYSAM c irc uit p ack, these
tests (Outpulse Relay Test, Analog Looparound Test, and External Modem
Present Test) do not run.
c. This test aborts if an external mod em is not administered.
SYSAM Reset Test (#909)
This test is destructive.
Order of Investigation Short Test
Sequence Long Test
Sequence Reset Board
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
SYSAM Reset Test (#909)(a) X X D
SYSAM Dual Port Ram Test (#910)(a) X X D
Sanity Handshake Test (#911) X X ND
Time of Day Clock Test (#913) X X ND
G3-MT Looparound Test (#915) X X ND
Outpulse Relay Test (#916) (b) X X ND
Analog Looparound Test (#917) (b) X X ND
External Modem Present Test (#912) (b)(c) X X ND