DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-752E-DIG-STA (Emulated Digital Line)
9
1003 ABORT The system could not allocate a tone receiver for the test. The system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test.
1. Use display port UUCSSpp to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the service state
of the port. If the port is in use, wait until it is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in
and the port is not busied out.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
7 FAIL Conference Test failed on primary channel. In some cases, users may not
notice disruption in service. In extreme cases, conferencing feature may
not work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being ab le to use this port.
15 FAIL The control channel between the processor and d igital circuit pack is not
transmitting properly. User impact may range from noticing nothing to not
being able to use the port. This could disrupt other users.
16 FAIL The second ary voice channel is not transmitti ng properly. User impac t
may range from noticing nothing to not being able to use this port.
1. Run circuit pack tests to check the Tone Generator circuit pack and
the Tone Detector circuit pack using the test board UUCSSpp
command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the test still fails, replace the Digital Line circuit pack.
Table 9-290. TEST #13 Voice and Control Channel
Local Loop Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page