DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1223PGATE-PT (Packet Gateway Port)
9
automatically loops b ack the signal at the po rt as shown in the the figure below.
Failure of this test indicates the existence of a fault in the p ort hardware on the
circuit pack.
Figure 9-76. Packet Gateway Port Local Loop-Around Test
This test aborts if calls are using the p ort or if the X.25 Access Link assoc iated
with the port is connected . To avoid this, first enter busyout data-module
extension or busyout port UUCSSpp or busyout link link#, which will cause all
calls and links using the port to be torn down.
Table 9-488. TEST #610 Packet Gateway Port Local Loop-Around Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT The X.25 Access Link is connected or the port is in use for a call. Execute
status packet-gateway-port UUCSSpp to determine when the port is
available for testing.
1. Retry the command when the port is idle. The port may be forced to the
idle state by executing a busyout port UUCSSpp command. This
command is destruc tive causing all c alls and links associated with the port
to be torn down.
2000 ABORT Response to the test was not received from the Packet Gateway circuit pack
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports on the board are not in use (Yellow LED is off). Reset the circuit pack
by issuing the busyout board UUCSS and the reset board UUCSS
commands.
2. If this result occurs again, replace the circuit p ack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page
Data
Set
Data
Set
Port
TN566
Packet
Gateway
RS423 Transmission Facility