DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-294AUX-TRK (Auxiliary Trunk)
9
Åudit Update Test (#36)
This test will send updates of the auxiliar y trunk port translation for all por ts on the
Auxiliary Trunk circuit pack that have b een translated. The update is
non-disruptive and g uards against possib le corruption of translatio n data
contained on the circ uit pack. No response messag e is expected from the circuit
pack once it rec eives translation updates. The port transla tion data includes:
Tru nk t y p e
DTMF time slot
Termination R/RC
Gain, high/low
End-to-end signaling, tone , and pause duration
129 FAIL The reflective 404-Hz tone test failed, no transmission was detected to or
from the port. The problem may be off-board.
131 FAIL The reflective 1004-Hz tone test failed. No transmission was detected to or
from the port. The problem may be off-board.
133 FAIL The reflective 2804-Hz tone test failed. No transmission was detected to or
from the port. The problem may be off-board.
1. To make sure the problem is on-board, disconnect the port from the
auxiliary equipment and retry test.
2. If the test fails, replace the circuit pack. Otherwise, if the test passed
after disconnecting the port from the auxiliary equipment, the problem
is off-board. Check the wiring and connections to the auxiliary
equipment and retry the test after reconnecting the port to the auxiliary
equipment. If the test fails, check the auxiliary equipment. See the
preceding proced ure for a failure with Error Code 7.
NOTE:
If the Looparound and Conference Test fails for all ports on a circuit
pack, a -5 volt po wer problem is indic ated. If a TN736 or TN752
power unit circuit pack is present, the 631DB AC power unit or the
676B power unit may be defective. The system may contain either a
TN736 or a TN752 power unit circuit pack OR a 631DB power unit,
but not both types of power units.
To investigate power problems,
refer to “CARR-POW”.
PASS Looparound and Conference Test is successful. This port is functioning
properly.
Table 9-133. TEST #33 Looparound and Conference Test — Continued
Error
Code Test
Result Description/Recommendation