DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1011MAPD-BD (MAPD Interface Circuit Pack TN802)
9
Error Log Entries and Test to Clear Values
Table 9-390. MAPD (TN802) Error Log entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test b oard UUCSS
1 (a) 0 Circuit pack removed or
SAKI Test (#53) MIN/
WRN2ON
2 (b)
18 (c) 0 busyout board UUCSS WRN OFF release board UUCSS
23 (d) 0 WRN OFF add ds1 UUCSS
125 (e) none 3 None MIN/
WRN3ON
257 65535 Control Channel Loop
Test (#52) MIN ON test board UUCSS l r 20
257 (f) Any None
513 (g) Any MIN/
WRN3ON
514 (h) 46086 MIN/
WRN3ON
769 (i) 46085 MIN/
WRN3ON
770 (j) 46096 MIN/
WRN3ON
1025 (d) 4363 NPE Audit Test (#50)
1281 Any Loss of Signal Alarm
Inquiry Test (#138) MIN/
WRN3OFF test b oard UUCSS
1537 (k) 46082 MIN/
WRN3ON
1538 (l) Any MIN/
WRN3ON
1793 Any Blue Alarm Inq uiry Test
(#139) MAJ/
MIN/
WRN 4
OFF test board UUCSS
2049 Any Red Alarm Inquiry Test
(#140) MIN/WR
N3OFF test board UUCSS
2305 Any Yellow Alarm Inquiry Test
(#141) MIN/
WRN3OFF test b oard UUCSS
Continued on next page