DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1017MAPD-BD (MAPD Interface Circuit Pack TN802)
9
Shutting down NT on the TN802

Before removing the TN802 circuit pac k from the carrier, shut Windows NTTM

down first by

following either proced ure

described in Table 9-391:

System Technician-Demanded T ests: Descripti ons
and Error Codes

Investigate tests in the order they are presented in Table 9-392. By clearing error

codes associated with the NPE Connection Audit Test, for example, you may also

clear errors generated from other tests in the testing sequence.

Error Type 1538
(hyperactivity)
also present? Then the switch:
Y Takes the circuit pack out-of-service due to hyperactivity
N Does not take the circuit pack out-of-service, but the
circuit pack has generated 50% of the messages
necessary to be considered hyperactive. This may be
normal during heavy traffic periods.
Table 9-391. Windows NT shutdown procedures
Step Faceplate button PC interface
1. Push the recessed button on the front
faceplate and hold it in. Click on the “Start” button in the lower, lefthand
corner.
2. “M shut” flashes on the LCD display Click on “Shut Down.”
3. When shutdown is complete, “MSHUT
#” displays (“ #” is blinking). Choose the “Shut down the computer?” radio
button.
4. Remove the circuit pack. Click on “OK.”
5. Wait for the message indicat ing that shutdown
is complete.
6. Remove the circuit pack.
Continued on next page