DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1389SNC-BD (Switch Node Clock Circuit Pack)
9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below when
inspecting errors in the sys tem. By clearing error cod es associated with the
configuration audit
for example, you may also clear errors g enerated from other
tests in the testing sequenc e.
NOTE:
Test #983 is not an actual demand maintenance test. This test numb er is
used to report results of execu ting of the clear firmware-counters
command. Refer to error codes fo r Test #777.
Configuration Audit (#759)
This test is non-destructive.
This test is run via the test board short or test board long command for SNC
circuit packs.
For SNC circuit packs, this test queries the SNC for SNCs and SNIs in the same
switch node carrier that the SNC ca n communicate with and c ompares this data
to the administered data.
Failures of this test cause entries in the error and alarm log s against Switch Node
Configuration (SN-CONF) with the board location of the SNC.
Order of Investigation Short Test
Sequence Long Test
Sequence Reset Board
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
Configuration Audit (#759) X X ND
Failure Audit(#777) X X ND
Processor Route Audit(#760) X ND
SNC On-Board Test(#778) X X ND
TPN Test(#779) X X ND
Switch Node Clock Reset Test(#780) X D