DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1492SPE-SELE (SPE Select Switch)
9
Figure 9-88. Duplication Interface Circuit Pack
Error Log Entries and Test to Clear Values
Notes:
a. Error 1 appears when one SPE Select Switch is in the AUTO position and
the other is in the select A or select B p osition. Placing both switc hes in
the AUTO position will retire the alarm immediately.
b. Erro r 257 a ppe ars wh en bot h SPE Selec t Swit ches a re in t he sele ct A o r
select B position for more that 6 hours. Placing both switches in the AUTO
position will retire the alarm immediately.
Table 9-568. SPE Select Switch Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Ch eck th e posi tion of the SPE-Sel ect sw itche s.
0 Any Any Any
1(a) 0 none WARNING OFF
257(b) 0 none MAJOR OFF
SPE-Select Switch
SPE-Select LED (Red)
Alarm LED (Red)
Test LED (Green)
Busy LED (Yellow)
O
O
O
SPE
AUTO
Override
B A
O
O