DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-747E-DIG-STA (Emulated Digital Line)
9
Notes:
a. Maintenance personnel have b usied out the port in q uestion. Make sure
that the port is released from bus yout by using the release port
UUCSSpp command.
b. The circuit pack has been removed or has been insane f or more than 21
minutes. To clear the error, reinsert or replace the circuit p ack.
c. Problems transmitting to the voic e terminal. This problem can b e caused
by defective wiring , which can cause var ying degrees of prob lems on
different types of sets. Sets such as the 7410 app ear to be more
susceptible to wiring problems than others.
d. An in-link maintenance error has g enerated an off-board warning due to
some problem with the link to the voice terminal. This c an be ignored if no
user complaints are received . Otherwise, make sure the voice terminal is
connected, c heck for defective wiring , check for a defec tive voice
terminal, and move voice termina l to a jack that is closer to the switc h
(number of feet of wiring betw een the jack and the switch). If the problem
still exists, replace the circuit pack. Once the problem has been resolved,
the alarm is retired after a predeter mined amount of time.
e. The local loop test failed. Each failure i ncrements the counter by 1 when
the local loop test fails. The counter is decremented when the loop test
passes. When the counter reaches a threshold of 3, an on-board MINOR
alarm is raised.
f. The NPE Crosstalk test failed. The counter is incremented by 1 when the
NPE Crosstalk test fails. The counter is decremented by 1 when the NPE
Crosstalk test passes. When the counter reaches a threshold of 3, an
on-board MINOR alarm is raised and the board is taken out of servic e.
2305 (g) 32770 None
3840 (h) 40965 None
3841 (i) 41029 None
2304 (j) None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
2. Major alarms may be down graded to Warning al arms based on the value used in the set options
command.
Table 9-288. Digital Line Error Log Entries - E-DIG-STA — Continued
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page