DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1097M/T-ANL (Maintenance/Test Analog Port)
9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the following table wh en
inspecting errors in the sys tem. By clearing error cod es associated with the
Analog Port Sanity Test
, for example, you may also clear errors g enerated from
other tests in the testing sequenc e.
NPE Crosstalk Test (#9)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected
time slot and never crosses over to time slots reserved for other connection s.
One or more Network Processing Elements (NPE) reside on each circu it pack
with a TDM Bus interface. The NPE controls port connectivity, gain, and provides
conferencing func tions on a per port basis. If the NPE is not working correctly,
one way and/or noisy connec tions may be observed. This test is p art of a port’s
long test sequence and takes approximately 10 to 20 sec onds to complete
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
Analog Port Sanity Test (#963) X X ND
Digital Looparound Test (#13) X X ND
NPE Crosstalk Test (#9) X ND
Hook State Inquiry (#566) X X ND
Clear Error Counters (#270) X ND
Table 9-436. TEST #9 NPE Cross Talk Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not ava ilable. The port may be in
use on a valid ATMS trunk test call.
1. Retry the command at 1-minute intervals a maximum of 3 times.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page