DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1732TDM-CLK (TDM Bus Clock)
9
TDM Bus Clock Parameter Update Test (#151)
This test updates the following internal p arameters on the Tone-Clock circuit
pack:
■Disable in-line duplic ation status messages.
■Disable in-line subrate frame maintenanc e messages (TN768, TN780
only).
■Set the PPM threshold at 60 PPM for TN768 and TN780. Set the PPM
threshold at 85 PPM for TN2182.
■Enable PPM threshold switching
■Set the number of slips to trigger

loss of signal

- currently 30 per 5
millisecond perio d
■Enable the on-board synchronization s witching algorithm (see ab ove)
■Enable holdover operation (TN2182 only).
This is not a test and will always pass without id entifying or reporting any
Tone-Clock circuit pac k errors
Table 9-649. TEST #151 TDM Bus Clock Parameter Update Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The Tone-Clock circuit pack parameters have been successfully updated.
Continued on next page