DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1287PMS-LINK (Property Management System Link)

9
Link Retry Test (#215)
This test sends a message to the PMS software process to make a d ata call to the extension where the PMS device connects. If the PMS Link is already up, then this test passes without making any d ata call.
Table 9-505. TEST #213 Link Tear Down Test
Error
Code Test
Result Description/ Recommendation
40
50 ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
1010 ABORT The PMS Link has been bus ied out and plac ed in the out-of-service st ate.
1. Enter release pms-link command to release the PMS Link from busyout
state.
2. Retry test pms long command to execute th e test.
2012 ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
FAIL Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
PASS The PMS Lin k is tor n down .
Table 9-506. TEST #215 Link Retry Test
Error
Code Test
Result Description/ Recommendation
10
20 ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
30 ABORT Internal system error.
1. Refer back to the ‘‘Procedures for Restoring the PMS Link’’ section for
resolution.
1010 ABORT The PMS Link has been busied out and placed in the ou t-of-service state.
1. Enter release pms-link command to release the PMS Link from
busyout state.
2. Retry test pms command to execu te the test.
Continued on next page