DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1753TIE-DS1 (DS1 Tie Trunk)
9
1018 ABORT The test was disabled via translation. You may want to determine why the
test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Administration’
screen is set to ’n.’ To enable the test, change the trunk administration
and enter ’y’ into the ’Maintenance Test’ field.
2. Repeat the test.
1020 ABORT The test did not run due to an already existing error on the specific port or
due to a more general circuit pack error.
1. Examine the error log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2. Retry the test.
1040 ABORT The test is invalid for this trun k port because it is administ ered as an access
endpoint.
1. Use display port to verify that this port is administered as an access
endpoint. In this case the test should abort.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2053 ABORT/
FAIL 1At least one of the following errors is found on the DS1 circuit pack: 1281:
Loss of Signal 1793: Blue Alarm 2049: Red Alarm 2305: Yellow Alarm 1537:
Hyperactivity
1. Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD/UDS1-BD Maintenance
documentation for the l isted error types.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-656. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page