DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-157ATM-BCH (ATM B-Channel Trunk)
9
Call State Audit Test (#257)
This test audits the internal call state b y asking the far-end switch fo r the ISDN
call state. The test is particula rly useful when you are trying to clear a hung call. If
the internal call state on the near-end differs from that on the far-end, the cal l is
torn down.
The ISDN specification allows up to 2 minutes for a rep ly. If a reply is not received
within the 2 minute window, the test logs a protoc ol time-out violation against the
associated signaling c hannel (ATM-DCH, Error Type 1).
NOTE:
PASS simply means that an appropriate message was c omposed and sent
to the far-end switch.
Table 9-67. TEST #257 Call State Audit Test
Error
Code Test
Result Description/ Recommendation
1018 ABORT Maintenance disabled
1. Enable maintenance by entering y in the Maintenance Tests? field on
page 2 of the change trunk-group form.
1019 ABORT Audit already in progress
1. Wait 2 minutes, and try again.
1113 ABORT Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check).
1114 ABORT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1116 ABORT Trunk out-of-service
1. Check the trunk service state (status trunk
grp#
/
mbr#
).
2100 ABORT Could not allocate needed resources
1. Retry the command up to 5 times at 1-minute intervals.
FAIL Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
PASS 1. Wait 4 minutes, then check the Error Log for call-state mismatches. If a
call state mismatch is found, the call is torn down.
Continued on next page