DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1658TAPE
9
Table 9-624. MSS Error Actions
Code Description
0 Unexpected interrupt from SBICC.
1 SBICC timed out during SCSI command.
2 DMAC generated error interrupt.
3 DMAC timed out without interrupt.
4 Tape self-test failed.
5 Tape external looparound test failed.
6 Command failed with bad SENSE key.
7 Tape could not be accessed.
8 Flaw detected in tape medium.
9 Unrecoverable hardware failure on tape.
10 Invalid parameter in SCSI command .
11 Media removed or tape reset.
12 Tape is write protected.
13 Tape reached end of medium.
14 Block reassigned on tape.
15 Block reassignment failed on tape.
16 Inconsistent capacity data
17 Device busy
18 Device reservation confli ct
19 Request sense failed
101 Unrecognized
opcode
.
102 Unrecognized
modifier
.
103
xlist_length
too long.
104 Invalid transfer address.
105 Intra-device c opy ranges overlap.
121 Device invalid for
opcode
requested.
122 Device non-existent.
123 Device is out of servic e.
124
to_byte
or
from_byte
is out of range.
125
to_byte
+
numbytes
is invalid or
from_byte
+
numbytes
is invalid.
Continued on next page