9-1620SYSAM (Circuit Pack)
9
SYSAM External Modem Present Test (#912)
This test is a nondestructive test on the remote ac cess line, and will run only if the
channel is idle. The test validates the presence of an external mode m with a
firmware invoked AT command. The test passes if the mod em responds with
“OK” to the AT command. This test also validates exte rnal modem administration.
This test will fail if an external modem is administered on a switch with an active
TN1648 suffix A.
This test is not allowed if the remote access line is i n use or if the SYSAM is on the
Stand by SPE in SPE Dupl ica tion O ptio n sys tems. Also, this t est m ust b e
administered for testing throug h the change system-parameters maintenance
screen.
FAIL SYSAM reported test failure. The system is not able to reliably contact any
remote maint enanc e fac ility w ith al arm da ta or d ialed into t hroug h the SYSAM
remote access port. The system continues to provide reliable service.
1. For an internal modem:
a. If SYSAM Ou tpul s e Relay test ( #916) is also faili ng, c heck for
prese nce o f SYSAM remo te ac cess line an d res o lve SYSAM remot e
access line problems.
b. If test #916 passes, the fault is on the SYSAM circuit pack, replace at
the earliest convenience. To replace the SYSAM circuit pack, refer to
"Replacing SPE Circuit Packs" in Chapter 5.
2. For an external modem:
a. Chec k the power to the modem.
b. Chec k the RS-232 connection from the external modem connector to
the modem. Transmit, Receive, RTS, and CTS signals must be
communicating between the MTP DUART hardware and the modem
hardware.
c. The SYSAM DUART or related circuitry on the processor circuit pack
may have failed. The circuit pack should be changed at your
convenience.
PASS SYSAM detected correct data through loop around connection.
1. If system cannot call remote maintenance facility or remote maintenance
facility cannot contact system, check with local Central Office for
problems with SYSAM remote access line.
Table 9-612. TEST #917 SYSAM Analog Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page