DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1798TONE-PT (Tone Generator)
9
Error Log Entries and Test to Clear Values
Notes:
a. A failure in the tone generation facility on the i ndicated c ircuit pack has
been detected . Replace the circuit p ack. See
How to Replace the Tone-Clock Circuit Pack
in the TONE-BD section.
b. The indicated Tone-Clock circuit p ack has been mad e unavailable via the
busyout tone-clock UUC command. It only app lies to systems which
have the High or Critical Reliability Op tion administered, b ecause only a
standby Tone-Clock circuit pac k may be made busy by that command. To
resolve this error, execute the release tone-clock UUC command for the
alarmed circuit p ack.
c. This error type indicates that t he circuit pack ha s been removed or has
been insane for more than 11-minutes. To clear the error, reinsert or
replace the circuit pack.
Table 9-671. Tone Generator Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test tone-clock UUC r 1
1(a) 17664 Tone Generator Audit/ MAJOR/ ON test tone-cloc k UUC r 2
Update Test (#41) MINOR2
2. MAJOR alarm if the alarmed Tone-Cloc k c ircuit pac k is not d uplicated ; MIN OR if it d uplicated w ithi n
the same Port Network.
18(b) 0 busyout tone-c lock
UUC WARNING OFF release tone-clock UUC
130(c) None MINOR ON test tone-clock UUC Sh
257(d,f) 17667 None MINOR ON
513(e,f) 17666 Tone Generator Audit/
Update Test (#41) MINOR ON test tone-clock UUC r 3
769 Any Transmission Test
(#40) MAJOR/
MINOR2ON test tone-clock UUC r 3
1025 Crosstalk Test (#90) MAJOR/
MINOR2ON test tone-clock UUC l r 2
1281(g) Any Tone Generator Audit/
Update Test (#41) MINOR ON test tone-clock UUC r 3