Maintenance Object Repair Procedures
9-882FIBER-LK (Fiber Link)
9
142 FAIL The SNI circuit pack (endpoint 1 of the fiber-link) has a fiber out of frame
condition, but no loss of signal cond ition. Also, no lightwav e transceiver is
connected to the SNI circuit pack.
1. Check that the connected circ uit pack is physically installed. The
connected circuit pac k is the other endpoint of the fiber-link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pac k.
2. Perform the Fiber Fault Isolation Procedure described in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected c i rc uit pack.
143 FAIL The SNI circuit pack (endpoint 1 of the fiber-link) has a loss of signal condition,
but no fiber out of frame condition. Also, a lightwave transceiver is connected to
the SNI circuit pack.
1. Check that the connected circ uit pack is physically installed. The
connected circuit pac k is the other endpoint of the fiber-link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pac k.
2. Perform the Fiber Fault Isolation Procedure described in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected c i rc uit pack.
144 FAIL The SNI circuit pack (endpoint 1 of the fiber-link) has a loss of signal condition,
but no fiber out of frame condition. Also, no lightwave transceiver is connected
to the SNI circuit pack.
1. Check that the connected circ uit pack is physically installed. The
connected circuit pac k is the other endpoint of the fiber-link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pac k.
2. Perform the Fiber Fault Isolation Procedure described in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected c i rc uit pack.
Table 9-336. TEST #989 SNI Fiber Out of Frame Query — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page