DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-737DUPINT (Duplication Interface Circuit Pack)

9
This test checks the ability of the ac tive Duplication Interfac e circuit pack to shadow writes that are within the shadowed address boundaries
Table 9-284. TEST #867 Local Loop-around Test
Error
Code Test
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Duplication Interface circuit packs are not set
to auto.
1. If the switches are loc ked because you are using a replacement
procedure, continue with this procedure to the step that directs you to
unlock the active SPE by moving both switches to auto. The next step
using the test duplication-interface long clear should not abort with
this error code.
2. If the switches are locked and a replacement proced ure is not being
used, start with step 6 of the SPE Duplication Channel Component
Replacement procedure for the standby Duplication Interface Circuit
pack at the end of the DUP-CHL section to avoid an undesired
interchange when unlocking the active SPE.
3. If this same abort is received with both switches in auto, Replace
Duplication Interface components starting with the standby Duplic ation
Inter face c ircui t pac k. Use SPE D uplic ation C hannel Compo nent
Replacement procedures at the end of the DUP-CHL section. In addition
to looking for failures, also check for the absence of this 1321 abort
code when testing after the procedure directs setting the switc h es to
auto after a component replacement.
1405 ABORT This test did not run because the Duplication Channel was busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1418 ABORT The HFAIL bit and/or the STDONE bit is in the wrong state. The active
Duplication Interfac e circuit pac k needs to be reset.
1. Run the test duplication-interface long command and follow
instructions for the Active DUPINT Reset Test (#870).
2. If test #870 passes and this test still aborts, escalate the problem.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The retrieved test data word that was looped around in the active
Duplication Interface circuit pac k did not match the inversion of the written
test data word.
1. Replace Duplication Interface components starting with the active
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of the DUP-CHL
section.
Continued on next page