DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-750E-DIG-STA (Emulated Digital Line)

9
Voice and Control Channel Local Loop Test (#13)
These tests check the information and c ontrol channels between the Switch Processing Element (SPE) and the Digital Line port circ uit. The SPE sends a message to loop around b oth the information and control ch annels for the port.
1003 ABORT The system could not allocate a tone receiver for the test. The system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test.
1. Use display port UUCSSpp to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the service state
of the port.
3. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. Wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in and
the port is not busied out.
1020 ABORT Test disabled by background testing. Use the status station command to
determine when the station is available for testing.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1
2FAIL The Network Processing Element (NPE) of the tested port is transmitting in
error. This causes noisy and unreliable connections.
Error code 1 = Crosstalk test failed on the primary channel.
Error code 2 = Crosstalk test failed on the secondary channel.
1. Replace the c irc uit pack.
PASS The port is correctly usin g its allocated time slots.
1. To ensure that this is not an intermittent problem, repeat this test a
maximum of 10 times.
2. If complaints persist, examine the station, connections, and wiring.
Table 9-289. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page