DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-742DUPINT (Duplication Interface Circuit Pack)
9
Table 9-287. Test #979 Active DUPINT HFAIL/STDONE Check Test
Error
Code Test
Result Description/ Recommendation
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The STDONE bit on the active Duplication Interface circuit pack is in the wrong
state.
2 FAIL The STDONE bit on the active Duplication Interface circuit pack is in the wrong
state.
3 FAIL The STDONE and HFAIL bits on the active Duplication Interface circuit pac k
are in the wrong state.
1. Run the test duplication-interface long command and follow instruc tions
for the Active DUPINT Reset Test (#870).
PASS The STDONE and HFAIL bits on the active Duplication Interface circuit pac k
are in the correct state.