DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1176PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module)
9
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Data received from remote loop back does not match data sent.
1. Check for faulty wiring.
2. Replace the data module and repeat the test.
3. If the test fails, replace the Digital Line circuit pack associated with the
data module and repeat the test.
PASS Data Module Looparound Test passed.
Table 9-467. TEST #175 Data Module Internal LoopAround Test — Continued
Error
Code Test
Result Description/ Recommendation