DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1486SNI-BD (SNI Circuit Pack)
9
146 FAIL The SNI circuit pack has a fiber out of frame condition, and a loss of signal
condition. Also, no lightwave transceiver is connected to the SNI circuit pack.
1. Check that the connected circuit pack is p hysically installed. The
connected circuit pac k is the other endpoint of the fiber-link if no DS1C
complex is administered (check via list fiber-link). Otherwise, if a DS1C
complex is administered, the connected circuit p ack is the DS1C circuit
pack connected to the SNI circuit pac k.
2. If a lightwave transceiver is not supposed to be present, go to step 2. For
example, an SNI connected to a DS1C circuit pack or an SNI with a
metallic connect ion does not have a lightwave transc ei ver. Otherwise,
check the lightwave transceiver connections. If OK, replace the lightwave
transceiver. If a fiber ou t-of-frame condition exists and lightwave
transceivers are used, check that the lightwave transceivers are of the
same type, that is, both are 9823a or both are 9823b. If they are not the
same type, replace one of the lightwave transceivers:
9823a is used for distances up to 4900 feet.
9823b is used for distances up to 25,000 feet.
3. Perform the Fiber Fault Isolation Procedure described in Chap ter 5.
4. Replace this SNI circuit pack.
5. Replace the connected circuit pac k.
PASS No problems associated with this test are detected on the SNI.
0NO
BOARD No board was detected by the test.
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset
instead of reseating the circuit pack. The reset board command should
almost never be used on an SNI. It may be necessary to use the reset
board command if the SNI circuit pack gets into a mode where it cannot
communicate with soft ware. If an SNI with active errors and alarm s is reset,
the errors and alarms may take a while to come back, therefore the reset
board command can mask real problems.
3. Run the test again. If it fails, the ID ch ip on board may be bad . Replace the
board and retest.
Table 9-566. TEST #989 SNI Fiber Out of Frame Query — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page