DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-62ANL-24-L (24-Port Analog Line)
9
Call the terminal equipment and verify that the terminal rings. If the
terminal does not ring, then rep lace it. Otherwise, issue the test port
UUCSSpp command, and follow the p rocedure for Test #48.
Aux Data 40977 indicates that no terminal equipment was connec ted
when ringing was attempted . Run the short test via the test port
UUCSSpp command, and follow the p rocedure for the results of Test #48.
b. This is a software audit error that does not indic ate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
c. This error type indicates that the c ircuit pack has b een removed or has
been insane for more than 11-minutes. To clear the error, reseat or replac e
the circuit pac k.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only 1 analog c ircuit pack in the
system has this problem, then replac e the circuit pac k. If only analog
circuit packs o n a particular carrier hav e this error, then the ringing
generator may not be connec ted to this carrier. If analog circuit packs on
many carriers have this error, then it is p robably a proble m with the ringing
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturb s the customer or the terminal equip ment,
disable it by s ettin g the Tests field on the change station extension form
to n. On some software releases, this also disab les Tests #6, 7, 161, and
35.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table belo w when
inspecting errors in the sys tem. By clearing error cod es associated with the
Battery Feed Test,
for example, you may also clear errors g enerated from other
tests in the testing sequenc e.