DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1505STBY-SPE (Standby SPE Maintenance)
9
that problem, (usually by rep lacing the circ uit pack). Then the SOH problem
shoul d eve ntuall y cle ar. If you lo ck-a nd-p ower- down the st andb y SPE to re plac e
the given pack, you’ll need to test it while in locked mod e until all tests pass and
then u nloc k and wait f or syst em sof tware to re-i nitia lize t he sta ndb y SPE. Only
then should you expect stan dby SOH to be improved to level
functional.
If neither the recent interchange mod e nor a standby component al arm exist, but
standby SOH persists at level
partially functional
, escalate the problem.
Error Log Entries and Test to Clear Values
Notes:
a. Indicates that a single hand shake attempt has failed. Use "status spe" to
see if handshake is down. If "status spe" indic ates that handshake is up,
ignore this error. If handshake is d own, see
Resolving Handshake Failure
.
Table 9-569. STBY-SPE Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level
On/Of
f
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test spe-standby l
1(a) Standby SPE Handshake Test
(#919) MAJOR OFF
18(b) busyout spe-standby WARNING OFF rel spe-standby
103(c) None MINOR OFF test spe-standby l
257(d ) standb y SPE stat us que ry
(#855) MAJOR OFF
260(e) s tandb y SPE stat us que ry
(#855) MAJOR OFF
514(f) None MAJOR OFF
770(g) standby SPE TO D Com parison
Test (#858) MINOR OFF test spe-standby l
1025(h ) standb y SPE statu s quer y
(#855) MAJOR OFF test sp e-standby l
1281(i ) any st andb y SPE statu s quer y
(#855) MAJOR OFF
1537(j ) any st andb y SPE con figur ation
Matchup test (#920) MAJOR OFF test spe-standby l