DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1837UDS1-BD (UDS1 Interface Circuit Pack)
9
This error will isolate the board from the Packet Bus and rais e an alarm. If
the Packet Bus is not alarmed, enter the following commands: busyout
board UUCSS, reset board UUCSS, test board UUCSS, release board
UUCSS. This should clear the alarm and restore the b oard to the Packet
Bus.
If the problem persists, and there are no PKT-BUS alarms, then replace
the circuit pac k.
w. For later releases of G3V4 and beyond, only error 3585 will show that t his
board is receiving mi sframes and the AUX data shows the last misframe
count that was reported.
x. These errors are not service-affecting. No acti on is required. These errors
are reported by the c ircuit pack when it rec eives a bad control c hannel
message from the switch. The auxiliary data identifies the following error
events:
y. The UDS1 Interface circuit pack has detected a transient hardware logic
error (for example, program log ic inconsistency). This error will d isappear
when no faults are detected for 100 minutes. The value in Aux Data field
indicates the type of hard ware problem.
z. Bad Translation RAM Location Found Error. This error is not
service-affecting. No ac tion is required. A Bad Translation RAM is
detected, bu t the call continues by using another translation location.
aa. LAN Receive Parity Error. This error occurs when the circuit pack detects
an error in a received frame from the Packet Bus. These errors are most
likely caused by a Pac ket Bus problem, but ma y be due to a circ uit pack
fault.
Refer to the PKT-BUS Maintenance documentation to determine if the
problem is isolated to this c ircuit pack or if the problem is caused by
Packet Bus faults.
ab. Error 3900 is used to give status information on a CPE Loopback Jack
Test. The value in the Aux Data field indicates the status of the loopb ack
test.
4096 Bad major heading
4097 Bad port number
4098 Bad data
4099 Bad sub-qualifier
4100 State inconsistency
4101 Bad logic al link
1. Test is currently running.
2. Test failed because loopback could not be ac tivated.
3. Test failed because test pattern could not be detected .
4. Test has been terminated.