DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-756EMG-XFER (Emergency Transfer)
9
Emergency Transfer Status
The status cabinet UU c ommand shows the location of the ET switches and the
current status of ET in the designated c abinet as follows:
Error Log Entries and Test to Clear Values
System Technician-Demanded T ests: Descripti ons and Error Codes (Multi-Carrier)
Always investigate tests in the order p resented in the table be low. By clearing
error codes associated with the
Battery & Battery Charger Query Test,
for
example, you may also clear errors g enerated from other tests in the testing
sequence.
on ET is manually invoked.
off ET is manually prevented.
auto+ ET is invoked and under system co ntrol.
auto- ET is not in effect and is under system co ntrol (normal
operating state).
unavailable The switch setting(s) is not availab le.
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test environment UU
1 0 Emergency Transfer
Query (#124) MAJOR ON test environment UU r 3
257 0 Emergency Transfer
Query (#124) WARNING ON test environment UU r 3
Table 9-292. System Technician-Demanded Tests: EMG-XFER (Multi-Carrier
Cabinets)
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
Battery & Battery Charger Query Test (#5) (a) X X ND
Continued on next page