DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-450CONFIG (System Configuration)
9
The Error Type field specifies the carrier and slot loc ation of the circuit pac k that
caused the error as indi cated in Table 9-188. If the Error Type field is greater than
1000, subtract 1000 from the Error Type field before con sulting the table.
If more than one CONFIG error is logged with an Aux Data of 1 at the same time,
inves tiga te any EXP-INTF (Exp ansi on Int erfac e) er rors b efore proc eedi ng. On ce
the port circuit p ack location has been d etermined from Table 9-188, use the list
configuration all command to determ ine if the circuit pack is in serted. If not,
insert the pack. If the c ircuit pack has already b een inserted but the error
persists, replace the c ircuit pack.
Converting Aux Data to Port-Network Number
Aux Data Port-Network Number
01
12
23
34
45
56
67
78
89
910
10 11
11 12
12 13
13 14
14 15
15 16
16 17
17 18
18 19
19 20
20 21
21 22