DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1855UDS1-BD (UDS1 Interface Circuit Pack)
9
Table 9-688. TEST #139 Blue Alarm Inquiry Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more of
the following symptoms may be exhibited.
1. The UDS1-BD tests (such as test 138 and test 139) are aborting with error
code 2000.
2. The tests run on the ports of this circuit pac k are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
properly installed .
When hyperactivity occurs, the circuit pack is isolated from the system, and all
of the trunks for this circuit pack are placed into the out of service state. The
system will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the UDS1 interface circuit pack is restored to normal
operation. All of the trunks for the UDS1 interface circuit pack are then returned
to the in service state. Hyp eractivity is often caused by the associated facility. In
such a case, faults (such as slips, misframes, or blue alarms) would be entered
in the error log. In addition, many hardware errors would be logged against the
associated trunk circuits. If the facility is OK and the error occurs again after 15
minutes, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL The remote DS1 endpoint is out-of-servic e.
1
1794 FAIL The UDS1 Interface circuit pack detects a Line Loopback Alarm (LLB).
If the UDS1 interface circuit pack connects to a T1 facility, call the vendor of the
T1 carrier to diagnose the remote DS1 endpoint.
If the UDS1 interface circuit pack connects directly to a switch, c all the system
technician of the remote switch to diagnose the DS1 endpoint.
If the UDS1 interface circuit pack connects directly to a line-side terminating
device (for example, a PRI terminal adapter), call the vendor of the terminating
device to diagnose the equipment.
Continued on next page