DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-216ATM-INTF (TN2305/6)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 23: ATM Expansion Interface circuit pack is administered
through a change circuit-pack command, b ut has not been inserted into
the system. Insert the circuit p ack.
b. Error Type 125: A wrong circuit pac k is located in the slot where this c ircuit
pack is logic ally administered. To resolve this problem, either remove the
wrong circuit pac k or insert the logically administered circuit p ack.
c. Error Type 217: The ATM circuit pack is physically p resent but has not
been given a personality. Remove the circui t pack or administer it using
the add atm pnc
command or add atm trunk command .
LED Condition LED
Red Board is not healthy Solid on never off
Red
Green Board is in the processes of booting Red: solid on
Green: 200 ms on 200 ms off
Green Maintenance is running tests on the
board Solid on (off when
maintenance completed)
Yellow Fiber LOS 100 ms on, 100ms off
Yellow Signal to the ATM switch is down 500 ms on, 500 ms off
Table 9-93. ATM-INTF Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
23(a) 0 None WAR OFF
125(b) None MIN ON
217(c) 0 None WAR OFF