DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-217ATM-INTF (TN2305/6)

9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Failure of this test is not logged in the Error Log.
Control Channel Loop-Around Test (#52)
This test is non-destructive. This test queries the c ircuit pack for its c ircuit pack code and vintag e and verifies its records.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
Control Channel Loop Around Test (#52) X X N
Table 9-94. TEST #52 Control Channel Loop-Around Test
Error
Code Test
Result Description/ Recommendation
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL The circuit pack failed to return the circuit pac k code or vintage.
1. Retry the command a few times for a maximum of 5 times.
2. If the problem continues to fail, reset the circuit pack.
3. Retry the command a few times for a maximum of 5 times.
PASS Communication with this circuit pack is successful.
Any NO
BOARD This is normal if the test is being done when:
the board is not phys ically in the system.
the system is booting up.
Otherwise, there is some inconsistency in the data kept in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in the process of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page