DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-720DUP-CHL (Duplication Interface)
9
Table 9-279. TEST #876 Memory Shadowing Test
Error
Code Test
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Duplication Interface circuit packs are not set to
auto.
1. If the switches are locked because you are using a replacement proced ure,
continue with this proc edure to the step that d irects you to unlock the active
SPE by moving both switches to auto. The next step using the test
duplication-interface long clear should not abort with this error code.
2. If the switches are loc ked and a replac ement procedure is no t being used,
start with step 6 of the SPE Duplication Channel Component Replacement
procedure for the standby Duplication Interface Circuit p ack at the end of
this DUP-CHL section to avoid an undesired interchange when unlocking
the active SPE.
3. If this same abort is received with both switches in auto, Replace
Duplication Interface components starting with the standby Dup lication
Interface circuit pack. Use SPE Duplication Channel Component
Replacement procedures at the end of this DUP-CHL section. In addition to
looking for failures, also check for the absence of this 1321 abort code
when testing after the p rocedure direct s setting the switches to auto after a
component replacement.
1322 ABORT Memory shadowing is off, but not inhibited by the standby SPE.
1. Shadowing may not be turned on yet, so use release spe-standby if the
standby is busied out, wait 5 minutes and run the test again. If the long
duplication-interface demand test was being used, investigate any failure or
abort from test #872 because this test is expected to turn on shadowing.
2. Rerun the test; if the same 1322 abort occurs again, use the display alarms
command and select Category spe. If any maintenance objects other than
DUPINT or DUP-CHL have MAJOR alarms, fix these problems. Problems
causing MAJOR alarms for MEM-BD, PKT-INT, SYSAM, H-ADAPTR, and
SW-CTL should be repaired first.
3. Rerun the test; if the same 1322 abort occurs again, look for other DUPINT
or DUP-CHL test failures by using the busyout spe-standby if not already
busied out and the test duplication-interface long clear commands. Fix
these problems according to the service doc umentation for these packs.
4. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure describ ed in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
Continued on next page