DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-158ATM-BCH (ATM B-Channel Trunk)
9
ISDN Test Call Test (#258)
This non-destructive test performs a far- end looparound test over an ATM-BCH
trunk if
the trunk is IN-SERVICE, MAINTENANCE/NEAR-E ND, or
OUT-OF- SERVICE/NEA R-END
no calls are active on the trunk
the system uses country protoc ol 1 (including US) or the far-end has
looparound cap ability
The test sets up a call to a far-end switc h over the ATM-BCH trunk. Then the
digital port on a TN711D Maintenanc e/Test circuit pack sends a bit p attern to the
far-end and bac k. If the received pattern ma tches that sent, the test passes. If
there are differences, it fails.
Synchronous Test Calls
You can initiate a synchronous outgoing test c all (including a test c all for
ISDN-PRI trunks) with these commands:
test trunk
grp#/mbr#
long [repeat #]
test board
UUCSS
long [repeat #]
test port
UUCSSpp
long [repeat #]
Table 9-68. TEST #258 ISDN Test Call
Error
Code Test
Result Description/ Recommendation
4 ABORT Signaling channel problem
1. Look for errors or alarms against the ‘‘ATM-SGRP (ATM Signaling
Group)’’ and ‘‘ATM-DCH (ATM D-Channel Port)’’ maintena nce objects.
8 ABORT TN230x circuit-pack problem
1. See the ‘‘ATM-INTF (TN2305/6)’’ maintenance object.
1004 ABORT B-channel in use.
1. See if a call is active. Run status trunk
grp#/mbr#
command.
2. If the service state is In-Service/Idle, retry the test.
1005 ABORT Bad configuration (for example, no Maintenance/Test circuit p ack)
1. Make sure that the Maintenance/Test Circuit Pack is inserted.
2. Repeat the test.
1018 ABORT Test call disabled
1. Enable Maintenance on the Trunk Group form.
Continued on next page