DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-903H-ADAPTR (MSS Host Adapter)
9
Host Adapter Status Test (#825)
This test verifies the following host adapter c ircuit operations:
The LED s on the MSSNET circuit pack can be turned on and off correctly.
Note that this only verifies that the control and status log ic for the LED s is
operating correc tly. The operation of the LED s may be tested visually by
using the test led command.
The MSS configuration information is correct (the h ost adapter is not in the
"held reset" state).
5102 ABORT Could not allocate the Mass Storage System to run this test
1. Retry the command at 1-minute intervals a maximum of 5 retries.
2. If the test continues to abort, verify that the daily translation-save operation
is not in progress (issue the display system-parameters maintenance
command to display the time for scheduled maintenance and the "y/n"
option for saving translation daily).
NO
BOARD The host adapter has been placed in the "uninstalled" state.
1. Verify that the host adapter is fully inserted and powered up.
2. Attempt a demand reset of the host adapter.
1FAIL The host adapter loop around test could not be run successfully.
1. Replace the MSSNET circuit pack (see the circuit pack replacement
section above) and issue the test mssnet long command.
PASS The host adapter loop around Test completed successfully. Look at the results
of other tests to see if it is operating correctly.
1. See the MSS Error Actions table at th end of the section on TAPE.
Table 9-345. TEST #824 Host Adapter Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page