DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-81ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
3. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
TN742 vintages 13,14 and 15
TN769 vintages 3,4 and 5
1018 ABORT Test disabled via administration. The default for the Test? field on the
station form is y; thus, you may want to determine why this field has been
set to 'n' on this station (this may be due to the ringing application test 48,
which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the Test? field to y.
1020 ABORT The test did not r un due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors ag ainst this port or the circui t
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a
system allocation to get information about the port or to put the port into a
service state failed or the attempt to put the port in connection with a tone
source failed (this could be a tone-clock p roblem). The tone-clock and
tone detectors could be having a communic ation problem, for example,
the companding modes could be out of sync hronization.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-33. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page