DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1948XXX-BD (Common Port Circuit Pack)
9
1008 ABORT Could not allocate a ringing circuit for one of the following reasons: all the
ringing circuits are in use; the ringing generator is defec tive; ringing generator
is not wired correctly.
1. If the test continues to abort, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to RING-GEN Maintenance
documentation and try to resolve any problem(s ). Then, go to Step 2.
b. If there are no RING-GEN errors, and the test continues to abort, issue
the test board UUCSS command on other TN742, TN769, or TN746
Analog circuit packs. If an ABORT with error code 1008 occurs for this
test on other circuit packs as well, then the ringing generator may be
defective or may not be wired properly. Refer to RING-GEN
Maintenance documentation for details. If an ABORT with error code
1008 does NOT occur on the other ports, then all four ring generators
are in use. Exit from this documentation.
2. Retry the command.
FAIL No ringing cur ren t is detected. The ring ing applic ation circuitry on t his circuit
pack prob ab ly is not healthy.
1. Retry the command again.
2. If the test continues to fail, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to the RING-GEN Maintenance
documentation and try to resolve any problem(s ).
b. If there are no RING-GEN errors, then replace the circuit pack.
3. Retry the command again.
PASS Ringing current is detected or this vintage of the Analog Line circuit pac k
does not support the Ringing Applic ation Circuit Test. Analog Line circuit
packs that DO NOT support Test #51 include TN712 Vintage 13 and earlier
and TN742 Vintage 3 and earlier.
Any NO
BOARD This is normal if the test is being d one when (a) the board is not p hysically in
the system or (b) the system is booting up. Otherwise, there is some
inconsistency b etween the physical c onfiguration and the d ata kept in the
system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-722. TEST #51 Ringing Application Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page