DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1167PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module)
9
Table 9-464. TEST #9 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the extension of
the data module port. Use the status data-module command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT System resources to run thi s test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals a maximum of
5 times.
1004 ABORT The port may be busy with a valid call.
1. Use the display port UUCSSpp command to determine the extension of
the data module port. Use the status data-module command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1020 ABORT Test disabled via background testing. Use status data-module command to
determine when the data module is available for testing.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2020 ABORT The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the previously existing error.
Continued on next page