DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1170PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module)

9
Data Module Audits Test (#17)

This is a series of six tests that are classified as hard ware audits. The processor

sends messages to the on-b oard microprocessor to p erform the following tests:

Switchhook Inquiry This is an updat e of the processor’s software

records based on the on-hook/off-hook status of the data module.

2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
7 FAIL Conference test failed on the primary information channel. In some cases, user
may not notice disruption in service. In extreme cases, conferencing feature
may not work at all.
14 FAIL The primary information channel i s not transmitting pro perly. User impac t may
range from noticing nothing to not being able to use this port.
15 FAIL The control channel between the processor and Digital Line circuit pack is not
transmitting properly. This can cause a wide range of effects. The user may
notice nothing or the port may be totally unusable. This could also disrupt
other users.
1. Run circuit pack tests to check the Tone Generator and the Tone Detector
circuit packs using the test board UUCSS short command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Digital Line circuit pack.
16 FAIL The secondary information is not tran smitting properl y. This can cause a wide
range of effects. The user may notice nothing or the port may be totally
unusable.
1. To be sure that this is not an intermittent problem, repeat this test up to a
maximum of 10 times to make sure it continues to pass.
2. If complaints still exist (poor data transmission), examine the data module,
connections, and wiring.
PASS Information and Control Channel Local Loop Test passed. All channels are
transmitting properly
Table 9-465. TEST #13 Information and Control Channel
Local Loop Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page