DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1762TIE-TRK (Analog Tie Trunk)
9
1001 ABORT System resources required to run this test are not available. This could be due to
a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to TDM-BUS
errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals a maximum of 5
times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx command to determine the trunk group/member
number of the port. Use the status trunk command to determine the service
state of the port. If the service state indicates that the port is in use, then the port
is unavailable for certain tests. You must wait until the port is idle before
retesting.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL This test can fail due to on-board or off-board problems. Off-board problems of
concern include EXP-PN and EXP-INTF faults, TDM-BUS faults, and faults
associated with the tone detectors/tone generators. Clear all off-board problems
before replacing the board. Keep in mind that a TDM-BUS problem is usually
the result of a faulty board connected to the backplane or bent p ins on the
backplane.
1. Reso lve any EXP-PN and/or EXP-INTF erro rs. i
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. Replace
the board only if the test fails.
Table 9-660. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page