DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-909HYB-LINE (Hybrid Line)
9
length of the wiring between the terminal and the switch). If the p roblem
persists, replace the c ircuit pack. Onc e the problem has been resolved ,
the alarm will be retired after a p redetermined delay.
b. Error type 18 indicates the port is busied out. The port is released with
release port UUCSSpp.
c. The circuit pack has b een removed or has been insane for more than 1 1
minutes. To clear the error, reinsert or replace the circuit p ack.
d. The EPF has been turned off due to an overcurrent condi tion at the voice
terminal. Check for defec tive wiring or a damage d jack, and make sure
the voice terminal is a Hybrid set. Once the prob lem has been resolved,
the alarm will be retired after a p redetermined delay.
e. The voice terminal has been disc onnected or there is a prob lem in the
wiring to the terminal. Make sure that the voic e terminal is connected or
check for defec tive wiring to the voice terminal.
f. Note that Error Types 769 and 1281 by themselves create Warning alarms
only, but if both are present, a Minor alarm will b e logged.
g. The port has reported a p roblem with the data link to the voic e terminal.
Ignore this error if there are no complaints ab out the voice terminal.
Otherwise, make sure the voice terminal is c onnected, c heck for defective
wiring, check for a d efective voice terminal, an d decrease the leng th of
the wiring between the voice terminal and the switch. If the p roblem
persists, replace the c ircuit pack.
h. The voice terminal went off-hook while in the disconnec t state. Use the
status station command to dete rmine the state of the terminal. The
off-hook should have moved the terminal to i n-service. No repair action is
necessary.
i. The link between the circuit pack and the voice terminal has b een
successfully reset. No repair ac tion is necessary.
j. Error 15 indicates a software audit error that does not ind icate any
hardware malfunction. Run the short test sequenc e and investigate any
errors.