DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-31ADX16D-P (16-Port AUDIX Digital Port)
9
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots that are out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and if it is not handling heavy traffic,
retry the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
1004 ABORT The port was put in use during the test. The test has been aborted.
1. Use display port UUCSSpp to determine the voice port extension of the
port. Use status station command to determine the service state of the
port. If the port is in use, wait until the port is idle before retesting.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-11. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page