DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-873FIBER-LK (Fiber Link)
9
215 FAIL The SNI circuit pack (endpoint 2) cannot communicate with the equipp ed SNI
in slot 15 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors.
2. If the SNI being tested has SNI-PEER Error Type 2561, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 2561, replace the SNI
in slot 15.
216 FAIL The SNI circuit pack (endpoint 2) cannot communicate with the equipp ed SNI
in slot 16 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors.
2. If the SNI being tested has SNI-PEER Error Type 2817, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 2817, replace the SNI
in slot 16.
217 FAIL The SNI circuit pack (endpoint 2) cannot communicate with the equipp ed SNI
in slot 17 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors.
2. If the SNI being tested has SNI-PEER Error Type 3073, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 3073, replace the SNI
in slot 17.
Table 9-333. TEST #759 Configuration Audit — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page