9-876FIBER-LK (Fiber Link)

9
Fiber Link Reset Test (#768)
This test is destructive.

This test resets both endpoints of the fib er link and is executed via th e reset

fiber-link F P command. Any DS1 CONV circuit p acks on the fiber link are not

reset. The reset fiber-link command should almost nev er be used. It may be

necessary to use it when the endp oint circuit pac ks enter a mode in which they

cannot communicate with so ftware. When necessary, always reset fiber

endpoints with the command instead of reseating the end point circuit pac ks.

239 FAIL The endpoint 2 SNI is administered to be connected to a DS1 CONV but is not
physically connected to a DS1 CONV (list fiber-link can be used to display
fiber link endpoints). If a DS1 CONV is not supposed to be connected to this
SNI, change administration to remove the DS1 converter complex from the fiber
link associated with this SNI by:
1. Check for the fiber that this SNI is an endpoint of by checking list fiber-link
2. Remove fiber-link for the fiber that this SNI is an endpoint of.
3. Add the fiber bac k via add fiber-link and this time do not administer the
DS1 converter complex. If a DS1 CONV should be connected to this SNI,
enter list fiber-link and verify that the fiber optic cable and /or metallic
cable connections are installed as administered.
240 FAIL The endpoint 2 SNI is physically connected to a DS1 CONV but is not
administered to be connected to a DS1 CONV (list fiber-link can be used to
display fiber lin k endpoints). Either add the DS1 converter complex to th e fiber
that this SNI is associated with by:
1. Check for the fiber that this SNI is an endpoint of by checking list
fiber-link.
2. Remove fiber-link for the fiber that this SNI is an endpoint of.
3. Add the fiber bac k via add fiber-link and this time administer the DS1
converter complex also. Or, remove the DS1 CONV connection and
connect the SNI directly to its administered fiber endpoint by entering list
fiber-link and verifying that the fiber optic cable and metallic cable
connections are installed as administered.
PASS The administered data and the circuit pac ks the SNI (s) can communicate with
match.
Table 9-333. TEST #759 Configuration Audit — Continued
Error
Code Test
Result Description/ Recommendation