DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-879FIBER-LK (Fiber Link)

9
SNI Fiber Out of Frame Query (#989)
This test is non-destructive.

The SNI circuit pack reports whe ther a fiber out of frame cond ition exists,

whether a loss of signal conditi on exists, and whether the lightwave transc eiver is

present.

2306 ABORT An SNI circuit pack on the fiber link is not responding to test requests sent by
software.
1. Run the test led switch-node for the switch node(s) that the SNI (s) reside
in to verify whether the LED s on the board(s) light. Follow the steps below
for the SNI (s) from step 1 that had no LED s light.
2. If the LED s on the other boards in the carrier light, but the LED s on this
board do not light, run test 760 via test board UUCSS l for the active SNC
in this carrier. Wait 5 minutes and then try step 1 one more time. If the LED
s on this board still do not light, replace this board. Replacing an SNI may
be service interrupting. Refer to the SNI-BD section for the procedure for
replacing an SNI.
3. If none of the LED s light for the boards in the same carrier as this board, fix
any problems associated with the connectivity of this carrier to the SPE.
Use list fiber-link to determine the fiber connections to this carrier. Check
the LED s on all SNI s and EI s and fix any fiber problems. Enter display
errors and r esolve any EXP-I NTF error entri e s asso ciat ed wi t h the PPN .
Also, resolve any SYNC, SNI-BD, SNC-BD, FIBER-LK, or SNI-PEER error
entries.
FAIL The SNI circuit pack reported failures or retransmitted a cleared failure
message.
1. If this is the first time this test was run, run the test again. If there were any
previous failure messages that software did not acknowledge, this test will
FAIL even if the failure messages indicate a FAIL to PASS transition, i.e., a
problem has gone away. If this test is run twice and FAILs both times, then
at least one problem still exists.
2. Resolve any errors or alarms (display errors and display alarms) for
SNI-BD, SNI-PEER, and FIBER-LK entries.
3. If no SNI- BD, SNI -PEER, or FIB ER-LK en tries exist i n the e rror an d ala rm
logs, retry the command.
PASS No problems are detected on the board.
Table 9-335. TEST #777 Failure Audit — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page