9-463DAT-LINE (Data Line Port)
9
1020 ABORT An existing error type 769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for error type 769.
1042 ABORT Port under test is a TTI port and has only default translations with no
assigned extension. The executed test requires an assigned extension
associated with the port being tested. Therefore, this test cannot
successfully execute.
1. If there is a need to execute the test on this particular port then the
tester must insure that the port is fully translated such that the port has
an assigned extension.
1180 ABORT There is no Maintenance/ Test circuit pack dig ital port available to carr y out
the test.
1. Check to see if the Maintenance/Test digital ports are present. (Enter list
config command; ports 02 and 03 should show).
2. If the digital ports (02 and 03) on the Maintenance/ Test circuit pack are
not present, refer to “M/T-BD”.
3. If the digital ports are present, retry the command at 1-minute intervals a
maximum of 5 times.
1181 ABORT No time-slots available to connect digital ports for the test.
1182 ABORT Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1340 ABORT No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
(ports 02 and 03 on the Ma i ntenance/Test circuit pack) are pres ent in
the system. At least one Maintenance/Test circuit pack must be present
in the PPN of a Release 5r system. There should be at least two such
ports present. If the ports are present, proceed to step 2. Otherwise,
determine why no ports appear in the list config display. Refer to
“M/T-DIG” and “M/T-BD”.
2. Look for M/T-DIG errors in the Error Log. If present, refer to “M/T-DIG”.
3. If the ports are present and no errors are logged against them, retry the
command at 1-minute intervals a maximum of 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit pack.