DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1744TIE-DS1 (DS1 Tie Trunk)
9
1020 ABORT The test did not run because of a previously existing error on the specific port or
a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281Loss of signal
1793Blue Alarm
2049Red Alarm
2305Yellow Alarm
1537Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL This can be due to on-board or off-board problems. Off-board problems of
conc ern inc lude EXP-PN and EXP-INTF f aults, TDM -BUS faul ts, and faults
associated with the tone detectors/tone generators. Cl ear all off-board problems
before replacing the board. Keep in mind that a TDM-BUS problem is usually
the result of a faulty board connected to the backplane or bent p ins on the
backplane.
1. Resol ve any EXP-PN and/or EXP-INTF error s.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Retest when the faults from steps 1, 2, and 3 are cleared. Replace the
board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles on this
port should be i nvestigated using other p ort tests and by examining sta tion,
trunk, or external wiring.
Table 9-653. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page