DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1309PNC-DUP (PNC Duplication)
9
different switch nodes. Investig ate any alarms against SN-CONF, SNI-BD,
FIBER-LK. The last two digits of the error code indicate the fib er-link
number (01-27) of the fiber that repo rted the retired alarm. List fiber-link
gives the location of the fiber.
p. A spontaneous PNC interchange took p lace in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_EAL. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. Add ing 1 to the last two dig its of the error code gives
the PN number of the port network that repor ted the retired alarm. (20003
points to port network 4.) List config port-network gives the cab inet
number associated with a p ort network.
q. A spontaneous PNC interchange took p lace in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_INL. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. Add ing 1 to the last two dig its of the error code gives
the PN number of the port network that repor ted the retired alarm. (20103
points to port network 4.) List config port-network gives the cab inet
number associated with a p ort network.
r. A spontaneous PNC interchange took plac e in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_HW. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. Add ing 1 to the last two dig its of the error code gives
the PN number of the port network that repor ted the retired alarm. (20203
points to port network 4.) List config port-network gives the cab inet
number associated with a p ort network.
s. A spontaneous PNC interchange took plac e in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_PER. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. Add ing 1 to the last two dig its of the error code gives
the PN number of the port network that repor ted the retired alarm. (20303
points to port network 4.) List config port-network gives the cab inet
number associated with a p ort network.
t. A spontaneous PNC interchange took plac e in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_DS1. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. Add ing 1 to the last two dig its of the error code gives
the PN number of the port network that repor ted the retired alarm. (20403
points to port network 4.) List config port-network gives the cab inet
number associated with a p ort network.
u. A spontaneous PNC interchange took plac e in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_SNIL. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. The last two dig its of the error code indic ate the
fiber-link number (01-27) of the fib er that reported the retired alarm. List
fiber-link gives the location of the fiber.