DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4

June 1999

Maintenance Object Repair Procedures

9-1315POWER

9
Note:
a. Check to see if the battery charg er is connected. If the c abinet is powered by a UPS, there is no battery backup , and this error can be ig nored.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below when inspecting errors in the sys tem. By clearing error codes a ssociated with the
Battery & Battery Charger Query Test,
for example, you may also clear errors
generated from other tests in the testing sequence.
3840(a) 1005 or
1028 Associated Battery
& Battery Charger
Query Test (#5)
test environment

UU

s r 1
1. Run the Short Test S equence first. If all tests pass, run the Long Test S equence. Refer to th e appropriate
test description and follow the recommended proc edures.
Table 9-512. System Technician-Demanded Tests: POWER
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
Battery & Battery Charger Query Test (#5) X X ND
AC Power Query Test (#78) (a) X X ND
Power Unit Query Test (carrier E) (#127) (b) X X ND
Power Unit Query Test (carrier D) (#127) (b) X X ND
Power Unit Query Test (carrier A) (#127) (b) X X ND
Power Unit Query Test (carrier B) (#127) (b) X X ND
Power Unit Query Test (carrier C) (#127) (b) X X ND
Emergency Transfer Query Test (#124) (c) X X ND
Cabinet Sensors Query Test (#122) (d) X X ND
External Alarm Lead Query Test (#120) (e) X X ND