DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1267PKT-INT (Packet Interface Circuit Pack)
9
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
A planned interchange may be caused b y 24 hour scheduled testing. During
this time the terminal will be held out of service but it should recover
automatically after 3 minutes.
1. Wait 3 minutes and retry the command.
1373 ABORT Could not establish the l ink loop around link to run this t est.
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2060 ABORT Packet link bus went down during maintenance looparound test.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
2. If there are errors associated with the Packet Bus, refer to the
maintenance information assoc iated with the Packet Bus.
2100 ABORT Could not allocate the nec essary system resources to run this test .
1. Retry the command at 1-minute intervals, a maximum of 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals, a maximum of 5 times.
NO
BOARD The Packet Interface circuit pack is administered but it is not detected as
being physically present.
1. If the Packet Interface circuit pack is present, replac e it.
2. If the Packet Interface circuit pack is not physic ally present, use the
display system-parameters maintenance command to check if the
Packet Interface circuit pack is administered as being p resent. If it is
administered, use the change system-parameters maintenance
command to change the Packet Interface circuit p acks administered to be
those actually present.
Table 9-500. TEST #886 Maintenance Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page